Monitor your wideband, SCPC and Beacons remotely with the affordable RCM-2150C monitors. Your 900 MHz to 2200 MHz monitoring solution!!
Model RCM-2150C L-Band Carrier Monitor
DTi's Remote Carrier Monitor products provide an economical solution for remote signal monitoring & analysis. Perfect for fast alignment of antennas & detecting / recording signal interference or signal anomalies from one or multiple remote locations. An excellent solution for offsite troubleshooting, monitoring, and analysis.
RCM-2150C Technical Specificationss
Frequency Coverage:
900MHz - 2200MHz
Span Width:
0-500MHz / Variable
Resolution Bandwidth:
3MHz, 1MHz, 300kHz, 100kHz, 10kHz
RF Sensitivity:
Greater than -100dBm Typical
Reference Levels:
Selectable -10dBm to -60dBm in 2, 5, or 10dB steps
Scale:
2, 5, & 10 dB/Div selectable
Dynamic Range:
60 dB Logarithmic @ 10dB resolution per division on Application Window. 40dB Logarithmic @ 5 dB resolution per division on Application Window. 20dB Logarithmic @ 2 dB resolution per division on Application Window.
Amplitude Accuracy:
+/- 1 dB typical
Frequency Accuracy:
+/- 1 kHz typical
Input Connector:
BNC, 50 Ohm standard
Size:
1 Standard EIA Rack Unit
19"W x 1.75"H x 16"D
Power Requirements:
85 - 265 VAC 50/60 Hz
Display:
Windows based DTI Graphical
User Interface
Optional Configuration & Accessoriess
RCM-2150C-2 RCM-2150C-4 RCM-2150C-6 Switch isolation- 65 dB
2 RF Input 4 RF Input 6 RF Input
Note: Specifications are based on Dominion Test Instruments control system and graphical user interface and may vary depending on the control system used. Please contact DTI for specifications based on the selected platform. Custom GUI options available, please contact DTi.
900 MHz – 2200 MHz Carrier Monitor
The RCM-2150C is the perfect solution for remote monitoring of your L-Band satellite carriers. Whether you are using the RCM-2150C for setting up and aligning your antenna or monitoring your carrier, the RCM-2150C reduces personnel costs associated with verifying your carrier in local or remote areas. The RCM-2150C is monitored in real time from a central location on your network, using a standard PC. You save time and money by allowing the Engineer or Technician to quickly monitor and troubleshoot a problem remotely without sending personnel to the site. This solution is "plug and play". The Ethernet RJ-45 port instantly enables a network connection to your LAN/WAN or other IP network resource. The RCM-2150C provides an extremely flexible and cost-effective way to network-enable one or many RCM-2150C units and monitor them from a central location.
Features & Benefits
Now supporting LINUX OS!
Comparative mask / template mode
Waterfall mode
Tuning and sweep accuracy w/ DIGISWEEP
Improved input sensitivity!
Email alerts / alarms to your Cell PDA or PC
Low profile 1RU rack mount design
Variable reference levels
Variable data point resolution
Center frequency tuning
Variable span width
Variable sweep rate / Single sweep mode
Video Bandwidth Filtering
Instant ZERO span
5 resolution bandwidths 3 MHz to 10 kHz
Coupled and uncoupled RBW selection mode
Multiple input options
Waveform mask alarm feature
Ethernet ready, internet ready
Unlimited ability to save and recall user setups
Alarm triggered/event triggered recording
Playback with event cues
User defined averaging & mean filter features
* contact DTi for your application
Applications
Teleport Carrier Monitoring
Broadcast TV Stations
Monitoring Oil Rig Data Carriers
Satellite News Gathering
Portable Fly-Aways
Greater input sensitivity! Finer tuning resolution! User selectable Variable Data Point display resolution! & Now supporting Linux OS!!
New 5.3.0.1 Control Additions!
Waterfall Mode Standard analyzer mode only show a changing snapshot of the current signal RF energy, waterfall shows a scrolling spectrogram, a 2-d plot of frequency vs time. Waterfall plots are a convenient way of viewing a time history of your data. Each successive measurement record is plotted along the z-axis making it easy to see trends in the data.
Envelope Alarm SENDS EMAILs to your PC or Phone / STARTS Event triggered recording
- The alarm panel offers two alarm solutions, waveform mask (represented above) and the high / low limits option. The waveform mask option allows a user to select an exact envelope of concern around the signal of interest. The user can adjust and select the desired sensitivity by selecting and manipulating the +/- Alarm Limits control variable. Selecting a smaller or larger number will affect the monitor area around the signal. The high / low alarm function allows a user to select a box area to monitor. With either alarm scenario the alarm will activate the alarm visual indicators and if the user has selected the option will then either start a recording or send an email notification based on the criteria determined by the user.
Auto Tune Feature Allows the user to define multiple setups of IP location, RF switch inputs, center frequency, reference level, span width etc… This is an excellent tool for monitoring both multiple locations (Remote Carrier Monitors / locations) and multiple RF inputs and center frequencies setups automatically. Allows up to 25 IP / locations and / or user defined setups.
Strip Chart / Log Utility The strip chart panel allows a user to monitor the amplitude of a selected signal and display the amplitude on an amplitude vs. time strip chart. The user can then recall the data for analysis.
The Strip charting log utility allows for recording of center frequency amplitude. Events are recorded and presented on time based event chart. Additional logging feature allows for tab delimited file that can be imported into your favorite spreadsheet program. The log files can be automatically saved and restarted on a daily basis and pulled up later for review of signal performance.
Comparative Mask & Template Mode Allows the user to save and recall template Mask for easy signal comparison & verification.
Email alerts/ alarms to cell/PDA or PC Software allows email alarms or alerts be sent instantly to notify the user of interference, loss of signal or any number of event triggered signal problems.
Now Supporting Linux With our latest release, DTi has added a LINUX option for those users who prefer LINUX OS.
We also continue to offer our software in 2000, XP and Vista.
Comparative Mask mode – allows a user to save & recall a sweep for comparison or analysis Single Sweep mode – allows the user to select from standard sweep, variable sweep or single sweep mode for ultimate convenience. Variable datapoint Resolution – VDR allows the user to set the display point resolution allowing faster sweep rates. Waterfall mode - waterfall shows a scrolling spectrogram, a 2-d plot of frequency vs/ time. Video Bandwidth Filter - The video bandwidth allows the user to select multiple video bandwidth filter settings / 10 Hz – 100 kHz. Variable Sweep Rate - The sweep rate feature allows the user to select various sweep rate settings / 0 – 10 Seconds. Instant Zero Span - One button activation for quick amplitude measurement. RBW Coupling - Selectable RBW coupling allows for optimum span setting / can be disabled for free span selection. IP Utility Toolbox - New IP toolbox for quick IP set up /configuration and network identification. Linux - Now supporting Linux OS.
Manufacture of test equipment and accessories for the Broadcast, Satellite, Wireless, RFID, CATV and Military markets.
Please contact us for more information. If you are experiencing problems with this site please notify our webmaster.